Super Reef Octopus CR 5000D Calcium Reactor
$655.99

SRO CR5000D 8in Dual Chamber Calcium Reactor

  • SKU: SRO-CR5000D

Dual Chamber Reactor Rated for Aquariums up to 1000 Gallons

Footprint: 18″ x 15.5″ | Body Diameter: 2x 8″ | Height: 23″ 
Recirculation Pump: Reef Octopus Water Blaster 5000

$655.99
Features
Overview

High performance reverse flow design, superior craftsmanship and a 2 year pump warranty are just a few of the features on the Super Reef Octopus calcium reactors. If you are concerned about calcium levels due to your calcium loving animals look no further than our SRO calcium reactors. All SRO calcium reactors come with our high water volume Water Blaster pumps which come standard with Silicone Carbide shafts and bearings, this means no worries of moving parts freezing up causing broken shafts. All SRO calcium reactors come with PH probe holders to monitor PH inside the first chamber of the reactor. Equipped with a PH probe holders to mount a PH probe to monitor Ph levels in the main reactor chamber and built in bubble counters to monitor Co2 drip rates. To help you meet the challenging task of maintaining alkalinity, calcium and trace elements, consider adding a Super Reef Octopus calcium reactor to your aquarium system. 

How it works

A calcium reactor is essentially a chamber full of aragonite, which is the crushed skeleton of ancient hard corals. Aquarium water is pumped through this chamber along with pressurized carbon dioxide (CO2). The CO2 lowers the pH in the chamber to an acidic level which dissolves aragonite media into the aquarium water. In addition to dissolving the calcium, this process also dissolves nearly all the minerals and trace elements the coral used in order to grow.

Automated Calcium and Alkalinity supplementation - When set up properly and used correctly, a calcium reactor can maintain or increase calcium levels with little to no maintenance.

MORE DETAILS

Calcium/Alkalinity Demand

- 1000 Gallon – Light Demand        |        800 Gallon – Medium Demand        |        700 Gallon – Heavy Demand 

Technical Specs

Body Size: 2 x 8″  
Footprint: 18″ x 15.5″
Total Height: 23″
Media Capacity: 
Inlet Size:  1/4"
Max Feed Rate: 150GPH 
Note: Suggest a feed pressure slightly higher than a full flowing influent

Recirculation Pump Information

Water Blaster 5000
Wattage: 60w

Warranty - 2 year warranty on pump and 1 year on reactor body 

FAQS

Necessary CR Components- CO2 regulator, PH controller, CO2 Tank, Small feed pump (Flow rate should be set at 1-2 liters per hour), CR media

In-sump or external applications

Media Replacement: You should only need to replace the reactor media as needed (approximately every 6 months to one year depending on demand)
CO2 Replacement: Replace carbon dioxide bottle as needed (also approximately every 6 months to one year, depending size and setup).
Commercial grade CO2 that is mostly used as a shielding gas for welding is good enough although grades used for beverage, medical or anaerobic applications could be cleaner but not readily available. Stay away from CO2 used for paint ball guns as it is often contaminated with oil or hydrocarbons.
PH Set Level: For calcareous media to dissolve efficiently, the pH will need to be around 6.5.
Calcium reactors are not built to sustain high pressures A slight pressure of 2 to 5 psi is about the range they can operate safely.  At between 5 to 10 psi most reactors will start leaking and at 10 psi you will be applying a 330 pounds of force to the top flange of a 6.5” dia. reactor chamber so anything above that is running the risk of blowing the top or cracking the reactor cylinder.

OPERATING AND ADJUSTING THE REACTOR
It is not difficult to operate and set up a calcium reactor if you get familiar with some basic principles of operation.

Basic rules of calcium reactor operation:

  1. A calcium reactor adds balanced amounts of calcium and alkalinity.  If you start with unbalanced levels, do not expect the reactor to balance the levels back. If the levels start unbalanced, they will remain unbalanced.
  2. A calcium reactors are not intended to increase or adjust alk or calcium levels.
  3. Your reactor system should be able to maintain a continuous and a stable effluent flow and CO2 bubble rate.
  4. Be very patient.  The reactor will take several hours to stabilize after each adjustment.

The Reactors Two Main Controls
The CO2 needle valve which is used to adjust the amount of CO2 being added to the reactor to lower the PH and the effluent valve that is used to adjust the amount of water that passes thru the reactor.

The more CO2 added, the lower the PH in the reactor will be and the faster the media will dissolve resulting in more alkalinity in the effluent.  The media starts dissolving at a PH of about 7.7. A PH range between 6.5 and 6.7 is acceptable for most CR medias. When PH levels reach below 6.5 the media will have a tendency to melt turning the media into a mud. *Note that calcite media will require a lower PH as far down to about 6.3.

The effluent control, the higher the effluent flow for a given PH in the reactor, the more alkalinity will be added to the aquarium. Note that changing the effluent flow rate will have an effect on the PH if the amount of CO2 is not changed.  When increasing the effluent flow without adding more CO2, the amount of CO2 in proportion to the effluent will be reduced and as a result the PH in the reactor will increase.

So in summary, changing the CO2 rate (bubble rate) will change the PH and amount of alkalinity in the effluent but will not affect the effluent flow.  Changing the effluent flow will change the PH so adjustments to the CO2 rate will be needed if it is desired to maintain the PH level previous to the effluent volume change.