Milwaukee pH Probe

https://www.coralvue.com/web/image/product.template/3376/image_1920?unique=9ecd6e9

SKU: CV-MA911B-2

MSRP: $ 54.00

  • Available Through Authorized Retailer
  • The Milwaukee pH Probe is a gel-filled glass electrode for measuring pH with compatible devices.
  • It is made for select monitors and controllers that accept a standard BNC pH probe connection.
  • The double-junction design helps reduce clogging during routine pH monitoring and testing.
  • The spherical glass tip gives more sensing surface area for faster response during pH readings.


Milwaukee
Milwaukee

Milwaukee Instruments is a leading European maker of digital electrochemistry devices.

pH Probe for BNC Monitors and Controllers

The Milwaukee pH Probe is a lab-grade, gel-filled glass probe for select monitors and controllers. It measures pH in aquarium, service, and general water testing applications where the device accepts a standard BNC pH probe connection.

This probe uses a double-junction design to help reduce clogging and a spherical glass tip to provide more sensing surface area. The gel-filled design means there is no electrolyte to refill, while the 2-meter cable gives extra routing length between the probe location and the monitor or controller.

Key Features:

  • Lab-grade glass pH probe for pH measurement.
  • Gel-filled electrode does not require electrolyte refilling.
  • Double-junction design helps reduce clogging.
  • Spherical glass tip provides more sensing surface area.
  • BNC connector works with compatible monitors and controllers.
  • 2-meter cable gives extra room for routing from the probe to the device.
  • Useful as a replacement pH probe for compatible Milwaukee equipment.

Ideal For:

  • Aquarium hobbyists replacing a worn pH probe on a compatible monitor or controller.
  • Service techs who need a gel-filled pH probe with a 2-meter cable for field testing.
  • Users maintaining pH monitoring equipment where a BNC probe connection is required.

Pro Tips:

  • Calibrate before use. New and replacement pH probes should be calibrated before they are trusted for aquarium or service readings.
  • Keep the glass tip wet. A dry pH probe can respond slowly or fail early. Store it in proper electrode storage solution when not in use.
  • Rinse between buffers. Rinse the probe with clean water before moving between calibration solutions. This helps avoid cross-contamination.
  • Clean before recalibrating a drifting probe. Buildup on the glass tip can make readings slow or unstable. Clean the probe before assuming it needs replacement.
  • Match the connector first. This probe uses a BNC connector. Confirm the monitor or controller accepts BNC pH probes before purchase.

What's Included:

  • 1 Milwaukee pH Probe

Specifications:

  • Brand: Milwaukee
  • Product Name: Milwaukee pH Probe
  • SKU: CV-MA911B-2
  • Product Type: pH probe
  • Probe Type: Glass pH electrode
  • Junction Type: Double junction
  • Fill Type: Gel-filled
  • Glass Tip: Spherical
  • Connector Type: BNC
  • Cable Length: 2 meters
  • Compatibility: Select monitors and controllers with a BNC connector
  • Use: pH measurement and monitoring
  • Electrolyte Refill Required: No

Manufacturer-Warrantied Brands

Some of the brands we carry are covered by the manufacturer's own warranty rather than a CoralVue warranty. Warranty terms vary by brand — we recommend visiting the manufacturer's official website or contacting them directly for current coverage details and the claims process.

If you're not sure which category a product falls into, our customer service team is happy to help.

Instructions:

  1. Remove the probe from its packaging and inspect the glass tip, cable, and connector for damage.
  2. Connect the BNC connector to the compatible monitor or controller.
  3. Rinse the probe tip with clean water before calibration.
  4. Calibrate the probe using the buffer values required by the monitor or controller.
  5. Rinse the probe between each calibration solution to avoid cross-contamination.
  6. Place the probe tip into the sample or monitoring location after calibration is complete.
  7. Allow the reading to stabilize before making decisions based on the pH value.
  8. Keep the probe tip wet during use and storage.
  9. Clean the probe when readings become slow, unstable, or difficult to calibrate.
  10. Store the probe in proper electrode storage solution when it is not in use.