Skip to Content
2in Grey Threaded PVC Union

Price:

$ 9.99


Air Silencer Black Cap
Air Silencer Black Cap
$ 2.92
$ 2.92
1/2in White 45° Degree PVC Fitting
1/2in White 45° Degree PVC Fitting
$ 0.99
$ 0.99

2in Grey Threaded PVC Union

https://www.coralvue.com/web/image/product.template/626/image_1920?unique=9ecd6e9

SKU: RF-1220GT

$ 9.99 9.99 USD $ 9.99

$ 9.99

Not Available For Sale

    This combination does not exist.

    • Premium Schedule 80 Structural Integrity: Injection-molded from thick-wall unplasticized gray PVC that handles continuous high pressure and eliminates system micro-cracking under mechanical stress.
    • Dual Internal FIP Threading: Precision-machined 2" Female National Pipe Thread (NPT) sockets accommodate male plumbing fittings for a fully tools-free takeaway block.
    • Leak-Proof EPDM Compression Ring: Equipped with a thick, self-seating internal rubber gasket that locks down tight to isolate creeping system water and salt crawl.
    • Three-Piece Quick Disconnect Layout: Disassembles cleanly into two independent end-connectors and a central collar nut to remove heavy pumps or skimmers for easy seasonal maintenance.
    • Fully Universal Chemical Compatibility: Completely non-toxic material properties protect marine lifespans, dosing systems, and closed-loop setups from chemical contamination.

    Heavy-Duty Schedule 80 2 Inch Threaded Grey PVC Union

    The Heavy-Duty Schedule 80 2 Inch Threaded Grey PVC Union (SKU: 164-108 / 858-020) is a premium commercial-grade structural decoupling fitting engineered by top global fluid handling manufacturers to establish quick-release access segments, safeguard plumbing versatility, and protect core pump assets inside large-scale marine reef aquariums, automated filtration sumps, and commercial aquaculture water loops. Hard-plumbing high-volume return circuits or primary drainage lines natively using basic structural couplings means that when a massive main return pump fails, or an expensive industrial inline UV sterilizer quartz sleeve cracks, the entire large-bore pipe run must be physically sawed apart with a pipe cutter. This dynamic three-piece compression union resolves this bottleneck entirely by segmenting structural lines into independent, decoupled service arcs.

    Calibrated to withstand elevated hydraulic stresses, this fitting features internal 2" Female Iron Pipe (FIP / FNPT) threads on both matching terminal collars. The distinctive dark grey polymer construction indicates a heavy Schedule 80 industrial wall thickness profile, offering substantially higher pressure ratings and structural stress tolerances than standard domestic white Schedule 40 hardware options. Nestled safely inside the union's central interlocking track sits a heavy-wall compression EPDM rubber O-ring. When the outer threaded locking collar nut is tightened down, it creates an absolute, watertight seal that handles up to 150 PSI of persistent fluid pressure while dampening harmonic motor hums and equipment-induced tremors beneath your tank stand.

    Key Features

    • Eliminates High Re-Plumbing Costs: Allows lightning-fast removal of primary return pumps, multi-stage gate valves, and multi-port reactors without destroying adjacent lines.

    • Fixes Post-Glue Misalignments: The rotational swivel action built natively into a loose union body allows you to perfectly adjust downstream piping angles even after nearby lines are locked in.

    • Resists Aggressive Corrosive Chemicals: Impervious to continuous salt saturation, heavy ozone injection tracks, macro-algae carbon dosing paths, and regular acid cleaning flushes.

    • (Note: This retail SKU contains (1) assembled 2" Schedule 80 threaded union assembly, which includes (2) FIP threaded end connectors, (1) outer collar locking nut, and (1) pre-installed EPDM rubber O-ring seal. External male adapters, Teflon thread tapes, and structural PVC pipes are sold under separate product categories).

    What’s Included:

    • (1) Complete 2" Schedule 80 Threaded Grey PVC Union Assembly

    • (1) Factory-Seated Leak-Proof EPDM Rubber O-Ring

    Technical Specs:

    • Official Manufacturing Title: 2" Schedule 80 PVC Threaded Union (FIP x FIP)

    • SKU / Industry Part Identifier: 164-108 (Spears Model: 858-020)

    • Inlet Port Connection Profile: 2" Female Iron Pipe Thread (FIP / FNPT NPT-Spec)

    • Outlet Port Connection Profile: 2" Female Iron Pipe Thread (FIP / FNPT NPT-Spec)

    • Material Wall Classification: Industrial Schedule 80 (Heavy-Wall Configuration)

    • Internal Gasket Compound: Commercial-Grade Ethylene Propylene Diene Monomer (EPDM) O-Ring

    • Maximum Safe System Pressure: 150 PSI at 73 Degrees Fahrenheit

    • Maximum System Thermal Tolerance: 140 Degrees Fahrenheit (60∘C Max Circuit Cap)

    • Official Compliance Standards: ASTM F1498, ANSI B1.20.1, NSF/ANSI 61 & 372 Certified Lead-Free

    • Primary Shell Color Finish: Dark Industrial Grey

    1. Examine your incoming lines. Ensure the male threaded adapters or fittings you are joining are clean, free of plastic burrs, and match the standard 2" NPT format.

    2. Wrap the male threads of your incoming pipe fittings with 3 to 4 uniform layers of high-density pink or grey Teflon thread tape. Spin the tape clockwise along the thread path.

    3. Separate the union by unscrewing the large central collar nut completely. Set the internal EPDM rubber O-ring aside in a clean zip-top bag to protect it from dust.

    4. Thread your prepared male fittings into the 2" FIP ends of the union blocks. Hand-tighten until snug, then use a strap wrench or wrench flats to turn an additional 1 to 1-1/2 turns. Do not over-torque.

    5. Inspect the internal compression track. Ensure it is entirely clear of tape fragments, re-seat the EPDM rubber O-ring firmly back into its circular groove, and line both piping ends up flush.

    6. Slide the large central union locking nut over the matching flange, thread it onto the receiving body block, and hand-tighten until secure. Turn on your system pumps and inspect for leaks.

    Pro Tips:

    • Never Apply Liquid PVC Solvent Cement to Threaded Union Ends.
    CRITICAL SEPARATION WARNING: This fitting is engineered with FIP internal threads, making it completely a mechanical screw-together connection block. Never apply clear liquid PVC primers or solvent welding glues to these internal threads. Liquid PVC cement breaks down the plastic walls chemically to fuse slip fittings. Applying it to threads will ruin the precision NPT pitch, weld your equipment permanently shut, and completely defeat the purpose of installing a quick-disconnect union.
    • Do Not Mix Tape and Pipe Dopes Simultaneously on Plastic Threads. When sealing the threaded connections, choose one thread sealant method exclusively. If you prefer Teflon tape, use tape alone. If you prefer paste-type non-hardening thread sealants, apply dope alone. Combining Teflon tape and paste dope simultaneously on plastic PVC threads creates a slick, over-lubricated tracking layer that can cause you to accidentally drive the male fitting too deep, splitting the heavy 2" grey union female housing right along the molded seams.
    • Inspect and Lubricate the Internal O-Ring During Annual Sump Cleans. Every time you take this union apart for annual return pump maintenance or system flushes, take an extra 30 seconds to slide the EPDM rubber O-ring out of its circular track. Wipe away any trapped detritus, calcified mineral scale, or salt creep using a fresh towel soaked in warm vinegar. Apply a microscopic film of pure, reef-safe silicone plumbing grease to the ring before reassembly. This keeps the rubber highly flexible and prevents it from pinching or tearing when you screw the union back together.