Skip to Content
ITC Reefculture PARwise PRO Light Meter

Price:

$ 398.99


Octo SRO 3000EXT Collection Cup
Octo SRO 3000EXT Collection Cup
$ 105.00
$ 105.00
Dymax Algae Wafers Supreme Fish Food, 60 g
Dymax Algae Wafers Supreme Fish Food, 60 g
$ 6.92
$ 6.92

ITC Reefculture PARwise PRO Light Meter

https://www.coralvue.com/web/image/product.template/58/image_1920?unique=9ecd6e9

SKU: ITC-PARWISEPRO

MSRP: $ 398.99

  • Available Through Authorized Retailer

The PARwise PRO uses revolutionary cPUR technology to measure the intensity and spectrum corals actually utilize (350-1100nm range), replacing outdated PAR measurements with coral-specific data, pigment analysis, and optimal placement recommendations for Android, PC, and Mac platforms.

ITC Reefculture
ITC Reefculture

UK-engineered reef innovation from light meters to pest control and coral farming tools

Revolutionary cPUR Technology Measures What Corals Actually Use

The PARwise PRO replaces outdated PAR measurements with cPUR (Coral Photosynthetically Usable Radiation), a groundbreaking technology that measures only the wavelengths and intensities corals can actually use for photosynthesis and growth. With an extended spectral range of 350nm to 1100nm (Near UV-A through infrared), it reveals wasted energy, detects heat waste, and provides pigment-level analysis to help you optimize every aspect of your lighting. Compatible with Android, PC, and Mac, and precise enough to pay for itself by saving just one coral.

Highlights:

  • Revolutionary cPUR measurement — coral-specific usable light, replacing outdated PAR
  • Extended 350–1100nm spectral range — Near UV-A through infrared
  • Pigment analysis — Peridinin, Fucoxanthin, Chlorophyll A/B/C/D, Beta-carotene
  • 12+ measurement parameters — cPUR, PAR, LUX, DLI, Kelvin, CQS, CRI, YPF, and more
  • Environment-specific calibrations — air, freshwater, and saltwater
  • Detects heat waste — identifies inefficient lighting in the IR range
  • Optimal coral placement — map light zones and match corals to their requirements
  • YPF measurement included — cPUR equivalent for planted aquariums
  • Lab-grade accuracy with a user-friendly browser-based interface (Chrome or Edge, free)
  • Works with Android (USB OTG), Windows PC, and Mac — device not included
  • ⚠️ Not compatible with iPhone or iPad

Why cPUR Outperforms PAR

Traditional PAR meters measure total photosynthetic light without distinguishing usable wavelengths — you can have high PAR readings that are essentially useless to your corals. cPUR weights measurements by coral pigment absorption, giving you a true picture of the light your corals can actually utilize. The result: smarter placement, better growth, and no more guessing.

PARwise PRO is Ideal for:

  • Reef aquarists optimizing coral growth and coloration
  • SPS and LPS coral keepers seeking spectrum optimization
  • Professional coral propagation and farming operations
  • Planted aquarium enthusiasts (YPF measurement included)
  • Aquarium stores and lighting manufacturers
  • Anyone ready to move beyond spectrum-blind PAR meters

Comprehensive Measurements (12+ Parameters):

  • cPUR: Coral-specific usable light
  • Spectrum: Complete wavelength distribution (350-1100nm)
  • PAR (PPFD): Traditional photosynthetic measurement
  • LUX: Standard light intensity
  • DLI: Daily Light Integral
  • cPUR Light Integral: Coral-specific daily measurement
  • Kelvin: Color temperature
  • YPF: Yield Photon Flux (plant equivalent of cPUR)
  • CQS: Color Quality Scale
  • CRI: Color Rendering Index
  • Purity: Spectral purity measurement
  • Dominant Wavelength: Primary spectral peak
  • CIE X/Y: Color space coordinates


PAR Range

0-6000 µMol/m2/s

Kelvin

1000-10,000 Kelvin

LUX

2-300000

Spectrum

350-1100nm

Optical Measurement Type

Point light source

Accepted light sources

Natural, LED, Fluorescent, Incandescent, Gas Vapour, HID

Measurement repeatability

< 0.5%

Calibration Uncertainty

+- 5%

Directional cosine corrector

Replaceable

Temperature response

Auto compensating

Ingress Protection Rating

IP68

Dimensions

85x40x20mm

Device Weight

130g

Outer Package Dimensions

24.5x 15.5x5.5 cm

Packaged Weight

215g


Revolutionary cPUR Technology:

  • cPUR (Coral Photosynthetically Usable Radiation): Measures only the wavelengths and intensity corals can actually use
  • Spectrum-Weighted Results: Excludes unusable wavelengths for accurate coral-specific measurements
  • Replaces Outdated PAR: PAR doesn't distinguish good from bad light—cPUR does
  • cPUR Light Integral: Time-based measurement replacing DLI with coral-specific data
  • The New Gold Standard: Purpose-built for coral lighting optimization

Extended Spectral Analysis:

  • 350nm - 1100nm Range: Near UV-A through infrared spectrum
  • Near UV-A Detection: Captures important 350-380nm wavelengths for corals
  • Infrared Analysis: Detects wasted energy as heat (can see flame heat!)
  • Comprehensive Coverage: All wavelengths affecting coral photosynthesis
  • Heat Waste Detection: Identify inefficient lighting producing excess heat

Advanced Pigment Analysis:

  • Absorption spectrum graph for key photosynthetic pigments
  • Peridinin: Important for zooxanthellae photosynthesis
  • Fucoxanthin: Critical brown/golden pigment
  • Chlorophyll A, B, C, D: Primary photosynthetic pigments
  • Beta-carotene: Accessory pigment for light harvesting
  • Understand photosynthetic efficiency at pigment level

Environment-Specific Calibrations:

  • Air measurements for above-tank testing
  • Freshwater calibration for planted tanks
  • Saltwater calibration for reef aquariums
  • Accurate readings in any environment

Warranty

CoralVue, Inc. hereby guarantees this product to be free from defects in material and workmanship for a period of:

  • 1 Year

Warranty is activated on the date of purchase.

This Standard Limited Warranty applies and is limited as follows:

  • To the product only as long as it remains in the possession of the original purchaser.
  • To the product that has not been subject to accident, misuse or abuse.
  • To the product that has not been modified, altered, defaced, or had repairs made or attempted by other than CoralVue, Inc.
  • That CoralVue be immediately notified in writing within ten (10) days of first knowledge of defect by owner or his agent.
  • That CoralVue, Inc. shall be given first opportunity to make any repairs, replacements or corrections to the defective construction within a reasonable period of time.
  • Under no circumstances shall CoralVue and/or the Manufacturer be liable by virtue of this warranty or otherwise for damage to any person or property whatsoever for any special, indirect, secondary or consequential damages of any nature however arising out of the use or inability to use because of the product defect.

System Requirements:

  • Compatible: Android devices with USB OTG support, Windows PC, Mac
  • Browser: Google Chrome or Microsoft Edge (both free)
  • Not Compatible: iPhone, iPad (Apple devices don't support USB OTG)
  • Device not included—use your existing smartphone, tablet, or computer

Getting Started:

  1. Follow the user instructions to get the PARwise PRO device up and running.
  2. Connect PARwise PRO to your device via USB
  3. Android: May require USB-C adapter (check device compatibility)
  4. PC/Mac: Direct USB connection
  5. Open Google Chrome or Microsoft Edge browser
  6. Navigate to PARwise PRO web app (URL provided with device)
  7. App will load automatically; no installation needed
  8. Select environment type: air, freshwater, or saltwater

Taking Measurements:

  • Choose measurement environment (air/freshwater/saltwater)
  • Submerge sensor in aquarium (or use in air for testing)
  • Position with sensor facing upward toward light
  • View real-time cPUR, spectrum, PAR, and all other parameters
  • Use pause function to capture readings at specific locations
  • Log data for documentation and comparison

Optimizing Your Lighting:

  • Measure cPUR at various depths and locations
  • Review spectrum graph and pigment absorption analysis
  • Compare cPUR values to coral requirements
  • Adjust light intensity, spectrum, or placement as needed
  • Use cPUR Light Integral to optimize photoperiod duration
  • Place corals in zones matching their cPUR requirements

For Coral Placement:

  • Measure cPUR throughout your aquarium
  • Map high, medium, and low cPUR zones
  • Match new corals to appropriate zones based on their needs
  • Saves corals from improper placement; pays for itself!

Additional Features:

  • Check IR range for heat waste from inefficient lighting
  • Use YPF measurement for planted tank optimization
  • Monitor CQS/CRI for visual appearance assessment
  • Track dominant wavelength and color characteristics
Similar Products
Accessory Products