IceCap 100 GPD Reverse Osmosis RO/DI Water Filtration System
SKU: IC-RI100
MSRP: $ 196,34
-
Available Through Authorized Retailer
- Clean, reef-ready water on demand; no power source, no plumber required.
- 100 gpd output; Dow Filmtec membrane with a 96-98% rejection rate
- Removes chlorine, chloramines, heavy metals, and dissolved solids before they reach your tank
- Refillable DI cartridge with color-changing resin so you know when to replace it, not guess
- 4-stage filtration: sediment → carbon block → RO membrane → DI resin
IceCap
Premium aquarium equipment without the premium price. Protein skimmers, pumps, reactors, heaters & more.
4-Stage RO/DI System for Reef, Saltwater, and Freshwater Aquariums
Key Features:
- Genuine Dow Filmtec TW30-1812-100HP membrane with a 96-98% typical rejection rate at rated conditions
- Refillable DI cartridge extends the life of your mixed-bed resin and reduces long-term consumable costs compared to sealed cartridge designs
- Color-changing DI resin provides a clear visual indicator that the resin is near exhaustion — no TDS meter required for basic monitoring
- Glycerin-filled pressure gauge allows you to confirm feed water pressure is within the 50-80 psi optimal range before and during production
- Clear filter canisters let you inspect sediment and carbon block condition without removing them from the bracket
- Auto shut-off valve stops production when the storage vessel is full; manual flush restrictor extends membrane life
- No electrical connection required — operates entirely on incoming line pressure
Ideal For:
- Reef aquariums where corals and inverts are sensitive to chloramine, heavy metals, and elevated TDS from municipal tap water
- Freshwater planted tanks that require 0 TDS source water for precise remineralization with specific mineral profiles
- Hobbyists performing 20-50 gallon weekly water changes who need consistent, high-volume RO/DI production
- Anyone on municipal tap water with seasonal chloramine treatment or variable source quality
- New reef builds that require a large initial volume of purified water in a short window
- Aquarists upgrading from a slower 50-75 gpd unit who want more output without stepping up to a higher-pressure 150-200 gpd system
Pro Tips:
- Check your feed water pressure before assuming the system is underperforming. The 100 gpd output rating assumes 65 psi feed pressure at 77°F with 250 ppm source water TDS. Many homes run 45-55 psi, especially on upper floors or at the end of a supply line. A low-pressure condition won't damage the system, but it will increase the waste-to-product ratio and noticeably reduce daily output. If your production seems slow, check the pressure at the gauge before replacing filters.
- Flush the membrane monthly even when you're not actively making water. If the system sits idle for more than a week, bacteria and biofilm can begin forming on the membrane surface. Running a 5-10 minute flush through the manual flush restrictor before collecting water is a simple habit that extends membrane life.
- Don't let your DI resin run to full exhaustion before refilling. Once the color-change resin fully shifts to amber/yellow, TDS in the product water has already begun to climb. If that water goes into your reef, you're adding the very contaminants the system is designed to remove. Check the cartridge window weekly during high-production periods and refill before the resin is completely exhausted.
- Store a spare sediment and carbon block filter on hand. These two stages protect the membrane from chlorine degradation and sediment fouling — the most common causes of premature membrane failure. Sediment and carbon blocks are inexpensive; a replacement Dow Filmtec membrane is not. Keeping spares available means you won't be tempted to run them past their service life.
100GPD System
IC-RI100
100* Gallons Per Day
16 x 6.5 x 15.5in (LxWxH)
3:1 Waste to Water Ratio
98% Rejection Rate*
Auto Shut Off Valve
Man. Flush Flow Restrictor
Installation Adapters
50-80psi Water Pressure*
1/4in RO Tubing Required
This Product
75GPD System
IC-RI75
75* Gallons Per Day
16 x 6.5 x 15.5in (LxWxH)
3:1 Waste to Water Ratio
99% Rejection Rate*
Auto Shut Off Valve
Man. Flush Flow Restrictor
Installation Adapters
50-80psi Water Pressure*
1/4in RO Tubing Required
Learn More
150GPD System
IC-RI150
150* Gallons Per Day
16 x 6.5 x 18in (LxWxH)
1.5:1 Waste to Water Ratio
99% Rejection Rate*
Auto Shut Off Valve
Man. Flush Flow Restrictor
Installation Adapters
60-80psi Water Pressure*
1/4in RO Tubing Required
Learn More
200GPD System
IC-RI200
200* Gallons Per Day
16 x 6.5 x 18in (LxWxH)
1.5:1 Waste to Water Ratio
98% Rejection Rate*
Auto Shut Off Valve
Man. Flush Flow Restrictor
Installation Adapters
65-80psi Water Pressure*
1/4in RO Tubing Required
Learn More*Low pressure may cause the RODI system to produce excessive wastewater. Water pressure can be increased by adding a booster pump before your RO/DI system.
Specifications:
- SKU: IC-RI100
- Output: 100 gpd (at rated conditions)
- Filtration Stages: 4 (sediment → carbon block → RO membrane → DI resin)
- RO Membrane: Dow Filmtec TW30-1812-100HP
- Typical Rejection Rate: 96-98%
- Waste-to-Product Ratio: 3:1
- Optimal Feed Water Pressure: 50-80 psi
- Maximum Feed Water Pressure: 150 psi
- Minimum Source Water Pressure (membrane spec): 65 psi
- Optimal Water Temperature: 77°F (25°C)
- Maximum Water Temperature: 90°F (39°C)
- Feed Water pH Range: 2-11
- Membrane Source Water TDS (rated conditions): 250 ppm softened tap water
- Membrane Recovery Rate: 15%
- Canister Size: Standard 10-inch
- Tubing/Fittings: ¼-inch push-connect
- Dimensions (L x W x H): 16 x 6.5 x 15.5 inches
- Power Required: None
Warranty
CoralVue, Inc. hereby guarantees this product to be free from defects in material and workmanship for a period of:
- 1 Year
Warranty is activated on the date of purchase.
This Standard Limited Warranty applies and is limited as follows:
- To the product only as long as it remains in the possession of the original purchaser.
- To the product that has not been subject to accident, misuse or abuse.
- To the product that has not been modified, altered, defaced, or had repairs made or attempted by other than CoralVue, Inc.
- That CoralVue be immediately notified in writing within ten (10) days of first knowledge of defect by owner or his agent.
- That CoralVue, Inc. shall be given first opportunity to make any repairs, replacements or corrections to the defective construction within a reasonable period of time.
- Under no circumstances shall CoralVue and/or the Manufacturer be liable by virtue of this warranty or otherwise for damage to any person or property whatsoever for any special, indirect, secondary or consequential damages of any nature however arising out of the use or inability to use because of the product defect.
Instructions:
- Check feed water pressure. Confirm your tap water line delivers 50-80 psi. Use the included glycerin-filled pressure gauge after installation to verify. If pressure is below 50 psi, a booster pump is required before the system for consistent output.
- Mount the bracket. Secure the filter bracket to a wall or cabinet in a location within reach of your feed water supply line and a drain for the waste line. Keep it out of freezing temperatures.
- Connect feed water. Use the included installation fittings to connect the system's inlet to your cold water supply line via ¼-inch push-connect tubing.
- Connect the waste line. Route the concentrate (waste) line to a drain using the provided fittings. Do not restrict or cap the waste line — this will damage the membrane.
- Connect the product line. Run the purified water output line to your storage container.
- Flush before use. Run the system for a minimum of 30 minutes before collecting water for use. Discard this initial flush volume to clear preservatives from the membrane and carbon fines from the block filter.
- Verify output TDS. Use a TDS meter on the DI output to confirm 0 ppm before using water in your system. Color-changing resin in the DI cartridge will begin shifting from blue/purple to yellow/amber as it exhausts.
- Stage 1 – Sediment filter: every 6-12 months
- Stage 2 – Carbon block: every 6-12 months
- Stage 3 – RO membrane: every 2-5 years
- Stage 4 – DI resin: when color change is visible, or when output TDS rises above 0 ppm