Seneye Spectra
SKU: SEN-000483
MSRP: $ 1.154,99
-
Available Through Authorized Retailer
The Seneye Spectra is a fully submersible lab-grade spectrometer with 1nm resolution (400-730nm) that measures PAR, PUR, Kelvin, and complete spectrum data to biologically optimize coral and plant lighting with species-specific placement recommendations.
Seneye
Seneye is a UK-made aquarium water-monitoring system that continuously tracks water parameters and alerts users to issues early.
Professional Underwater Spectrometry for Optimal Coral and Plant Growth
Highlights:
- Lab-grade nanospectrometer with 1nm resolution
- 400-730nm wavelength range for the complete visible spectrum
- Fully submersible with corrosion-proof construction
- Measures PAR, PUR (Photosynthetically Usable Radiation), Kelvin, and color average
- Species-specific analysis for corals, plants, and animals
- Ideal placement recommendations based on light requirements
- Data logging and export for professional documentation
- Factory customizable spectral response curve analysis
- Replaceable cosine corrector for long-term accuracy
- Intuitive software with USB drive installation
- Works offline or with internet updates
- Professional measurements in minutes
Seneye Spectra is Ideal for:
- Serious reef aquarium hobbyists optimizing coral growth and color
- SPS and LPS coral keepers seeking optimal light spectrum
- High-tech planted aquarium enthusiasts
- Professional coral propagation and farming operations
- Aquarium stores testing and comparing lighting products
- Lighting manufacturers validating product performance
- Marine biologists conducting research
- Aquaculture facilities optimizing production
- Understanding light degradation and bulb replacement timing
- Comparing different lighting technologies (LED, T5, halide)
- Optimizing coral placement by light intensity and spectrum
- Anyone seeking professional-grade underwater light analysis
Why Spectrum Matters:
- Blue Spectrum (400-500nm): Critical for zooxanthellae photosynthesis and coral coloration
- Green Spectrum (500-570nm): Secondary photosynthesis wavelengths
- Red Spectrum (620-730nm): Important for plant growth and some coral processes
PAR vs. PUR:
- PAR measures total light energy in the photosynthetic range but doesn't account for which wavelengths organisms actually use
- PUR measures biologically usable light weighted by spectral response curves of specific organisms
- Spectra measures both, giving you the complete picture
Professional-Grade Spectrometry:
- 1nm Resolution: Single nanometer precision for detailed spectral analysis
- 400-730nm Range: Complete visible spectrum measurement
- Cosine Corrector: Accurate readings regardless of light angle (replaceable for long-term use)
- Fully Submersible: Direct underwater measurements in actual aquarium conditions
- Corrosion-Proof: Built to withstand harsh saltwater environments
Advanced Light Measurements:
- PAR (Photosynthetically Active Radiation): Total light energy for photosynthesis
- PUR (Photosynthetically Usable Radiation): Spectrum-weighted light actually used by organisms
- Kelvin Temperature: Color temperature of lighting
- Color Average: Overall light color characteristics
- Complete Spectrum Graph: Visualize exact wavelength distribution
Biological Optimization:
- Select specific coral species for optimal placement analysis
- Choose plant species to ensure proper lighting
- Understand species-specific light requirements
- Factory customizable spectral response curves
- Growing species database with user base expansion
- Match lighting to target organism biology
Professional Software:
- Intuitive interface for quick measurements
- View spectral readings and biological implications
- Data logging for long-term tracking
- Export data for reports and documentation
- Works offline or with internet updates
- USB drive installation; setup in minutes
- Compatible with laptops and Windows tablets
Warranty
CoralVue, Inc. hereby guarantees this product to be free from defects in material and workmanship for a period of:
- 1 Year
Warranty is activated on the date of purchase.
This Standard Limited Warranty applies and is limited as follows:
- To the product only as long as it remains in the possession of the original purchaser.
- To the product that has not been subject to accident, misuse or abuse.
- To the product that has not been modified, altered, defaced, or had repairs made or attempted by other than CoralVue, Inc.
- That CoralVue be immediately notified in writing within ten (10) days of first knowledge of defect by owner or his agent.
- That CoralVue, Inc. shall be given first opportunity to make any repairs, replacements or corrections to the defective construction within a reasonable period of time.
- Under no circumstances shall CoralVue and/or the Manufacturer be liable by virtue of this warranty or otherwise for damage to any person or property whatsoever for any special, indirect, secondary or consequential damages of any nature however arising out of the use or inability to use because of the product defect.
Getting Started with Seneye Spectra:
- Insert the included USB drive into the Windows laptop or tablet
- Install Spectra software (works offline or with the internet)
- Connect the Spectra device to the USB port
- Software will recognize the device automatically
- Update software over the internet if desired (optional)
Taking Measurements:
- Submerge the Spectra device in the aquarium at the desired measurement location
- Ensure the cosine corrector is facing upward toward the light source
- Software displays real-time spectrum, PAR, PUR, Kelvin, and color data
- Move the device to different locations to map light distribution
- Log data for documentation and comparison
Species-Specific Analysis:
- Select target organism type (coral, plant, or animal)
- Choose specific species from the database
- View ideal placement recommendations based on current lighting
- Adjust coral/plant placement to match optimal light zones
- Modify lighting settings to improve the spectrum for the target species
Data Management:
- Save measurements with location notes
- Export data for reports or sharing
- Track changes over time as bulbs age
- Compare different lighting configurations
- Document professional installations
Maintenance:
- Rinse device with fresh water after saltwater use
- Cosine corrector is replaceable if damaged
- Corrosion-proof design requires minimal maintenance
- Store in a protective case when not in use
System Requirements:
- Windows laptop or tablet with USB port
- Provided USB drive for software installation
- Internet connection is optional for updates